Software Interfaces
Interfaces to pass information between applications
Off-the-shelf (AVEVA PI interfaces) and
Custom-built Interfaces
Automated Results has done extensive work with a wide variety of AVEVA and third party PI interfaces, which gather data from a remote device or system and feed the information into the PI Server. Data can come from any number of sources:
- DCS control system (ex. Emerson DeltaV)
- PLC controller (ex. Allen Bradley SLC 500)
- Databases (ex. MS SQL Server)
- Other Historians (ex. AspenTech SetCIM, Rockwell RSHistorian)
- HMI (ex. Wonderware, RSView)
- Other Applications (ex. SAP)
- Custom Equipment (ex. Scales)
Interfaces need to be designed to be robust and in mission-critical applications they also need buffering, store-and-forward and, where required, redundancy and failover so that data is not lost when a network link or server is unavailable.
AVEVA PI Interfaces
AVEVA offers over 450 PI interfaces to control systems. We have worked directly with the following:
- ABB including ABB WIS, ABB ULMA, 1190 Gauge System
- Allen-Bradley PLCs
- BacNet
- Bailey InfiNet 90 serial, SEMAPI, Serial CIU, OPC
- Batch File
- CANBus
- Cincinnati Leak Detector
- DDE
- Dukane Ultrasonic
- Emerson DeltaV OPC, PI-to-PI, PI Batch File
- Fisher Rosemount Provox/CHIP
- Foxboro AP50/51, AW70
- GE Cimplicity and 90-30/70 PLC
- GE Mark IV and Series 6
- GSE D3 OPC and TrendR
- Honeywell TDC and TDS with OPC to TPN servers
- Husky
- Intellution IFIX (standard, IBatch, IHistorian)
- Kaye Data Logger
- Measurex MXO, DaVinci, Roibox
- Moore ICI HLL/LIL
- Moore APACS
- Modbus, Modbus+, Modbus Ethernet
- Modicon Quantum PLC
- OPC DA and HDA
- Opto22 Snap
- Optivision with OPC HDA
- PI-To-PI
- PI-Ping full version
- RDBMS
- SNMP with SNMP traps
- Rockwell Automation RSBatch
- RSLinx
- Siemens Apogee
- Syslog
- TCP Response
- Westronic
- Wonderware (standard and OPC)
- Windows Performance Monitor
Third Party Interfaces
In addition to the large selection of AVEVA interfaces, we have also worked with 3rd party interfaces:
– COM connectors for Honeywell and AspenTech
– Matrikon
– Rovisys
– Kepware (Modbus, DDE)
Custom Interfaces by Automated Results
PI Interfaces
– Husky
– Dukane
– Cincinnati
– Bailey APS for NT
– Moore ICI HLL and LIL
– BacNet
Non-PI Interfaces
– SAP
– Sigmafine
– MS SQL server
– Acquidata (multiple)
– Optivision (multiple)
– Scales (multiple)
– Measurex Roibox
– SKF Marlin Inspection System
– Fibermaster Test System (multiple)
– TestStream
PI Interfaces, PI Connectors and Custom Interfaces
AVEVA provides several kinds of off-the-shelf data collection for the PI System:
- PI Interfaces: the established, configurable collectors for specific control systems and protocols, with local buffering so data is kept if the connection to the PI Server is lost.
- PI Connectors: collectors that discover the structure of the data source and can create the matching PI points and Asset Framework elements.
- PI Adapters: lightweight collectors for edge devices and industrial protocols.
A custom interface is the right choice when no off-the-shelf option fits, for example a proprietary device protocol, instrument files, a non-standard database or an application API. Whether off-the-shelf or custom, a reliable interface needs:
- Correct time stamps and time zones, and data quality flags.
- Buffering, store-and-forward and, for critical data, redundancy and failover.
- Least-privilege security for the source system and the historian.
- Health monitoring so a stopped interface is noticed quickly.
Collected data feeds a data historian and the applications built on it, such as manufacturing solutions and product genealogy.
Let us help you capture critical data for your company!
PI data collection lifecycle
PI interfaces and related data collection components need more than an initial connection. Planning should address source-system connectivity, interface installation and configuration, PI point mapping, buffering, startup and recovery behavior, performance monitoring, data quality checks and troubleshooting. The right approach depends on installed product versions and source-system requirements.
For organizations using older interface technologies, modernization planning should assess supported connectors, existing dependencies and the impact on downstream applications before changes are made.